Project goals
The ISO 362-3 standard, which has been valid since 2016, describes the measurement of the LUrban type testing level, consisting of a combination of the simulated pass-by in a test facility and a real pass-by on an external noise test track in accordance with Part 1.
In the test facility, the drive noise of the vehicle is measured and combined with the pure tire road noise of the external noise test track.