Sound power in an anechoic chamber

Acoustics

© Fraunhofer IBP
Measurement Sound power (enveloping measurement surface), sound intensity, localization of sound sources
Standard DIN EN ISO 3745
Measurement object Machinery and equipment, for example of ventilation and air-conditioning systems, and other noise sources


Technical data

Free room size (L × W × H) 9,3 m × 10,4 m × 10,3 m
Room volume 1090 m³
Entrance door (H × W) 1,89 m × 2,34 m


Special feature

Removable assembly grating as working area 4.0 × 4.0 m area, 5000 N/m² loading capacity

 

More information

  • Room-in-room construction with very low background noise
  • Vibrational isolation by using separate basement and steel springs
  • Lower cut-off frequency 80 Hz (according to standard)